In DC shunt motor starter, resistance is inserted in

Option 1: Field circuit

Option 2: Supply circuit

Option 3: Armature circuit

Option 4: Both field and armature


Correct Option: 3

Explanation

Field has high resistance already. High current occurs in armature, so resistance is inserted only in armature circuit.